- Anglo Belgian Corporation
- Markets
- Land-based power generation
16DV36
Up to 10,400 kWm (continuous rating)
Medium-speed (600-750 rpm)
IMO Tier III compliant (EGR or SCR)
2-stage turbocharging
12DV36
Up to 7,800 kW (continuous rating)
Medium-speed (600-750 rpm)
IMO Tier III compliant (EGR or SCR)
2-stage turbocharging
8DL36
Up to 5,200 kW (continuous rating)
Medium-speed (600-750 rpm)
IMO Tier III compliant (EGR or SCR)
2-stage turbocharging
6DL36
Up to 3,955 kWm (continuous rating)
Medium-speed (600-750 rpm)
IMO Tier III compliant (EGR or SCR)
2-stage turbocharging
16DZC
Up to 3,536 kWm (continuous rating)
Up to 4,000 kWm for special applications
SMART mechanical
IMO Tier III compliant *
12DZC
Up to 2,652 kWm (continuous rating)
Up to 3,000 kWm for special applications
SMART mechanical
IMO Tier III compliant *
8DZC
Up to 1,768 kWm (continuous rating)
Up to 2,000 kWm for special applications
SMART Mechanical
IMO Tier III comliant *
6DZC
Up to 1,326 kWm (continuous rating)
Up to 1,500 kWm for special applications
SMART mechanical
IMO Tier III compliant *
Evolve 20EV23
Up to 7,200 kWm (MCR)
Future-proof, multi fuel platform (liquid fuel, dual fuel, gas)
Medium-speed (750-1200 rpm)
IMO Tier III compliant
Evolve 6EL23
Up to 2,160 kWm (continuous rating)
Future-proof, multi fuel platform (liquid fuel, dual fuel, gas)
Medium-speed (750-1200 rpm)
IMO Tier III compliant
Evolve 4EL23
Up to 1,320 kWm (continuous rating)
Future-proof, multi fuel platform (liquid fuel, dual fuel, gas)
Medium-speed (750-1200 rpm)
IMO Tier III compliant
16DV36 genset
Up to 10,126 kWe @ 50 Hz
Up to 9,720 kWe @ 60 Hz
Medium-speed (600-750 rpm)
IMO Tier III compliant (EGR or SCR)
12DV36 genset
Up to 7594 kWe @ 50 Hz
Up to 7290 kWe @ 60 Hz
Medium-speed (600-750 rpm)
IMO Tier III compliant (EGR or SCR)
8DL36 genset
Up to 5,063 kWe @ 50 Hz
Up to 4,860 kWe @ 60 Hz
Medium-speed (600-750 rpm)
IMO Tier III compliant (EGR or SCR)
6DL36 genset
Up to 3,797 kWe @ 50 Hz
Up to 3,645 kWe @ 60 Hz
Medium-speed (600-750 rpm)
IMO Tier III compliant (EGR or SCR)
16DZC genset
Up to 3,395 kWe @ 50 Hz
Up to 3,057 kWe @ 60 Hz
Medium-speed (720-1000 rpm)
SMART mechanical
12DZC genset
Up to 2,546 kWe @ 50 Hz
Up to 2,292 kWe @ 60 Hz
Medium-speed (720-1000 rpm)
SMART mechanical
8DZC genset
Up to 1,697 kWe @ 50 Hz
Up to 1,528 kWe @ 60 Hz
Medium-speed (720-1000 rpm)
SMART mechanical
6DZC genset
Up to 1,273 kWe @ 50 Hz
Up to 1,146 kWe @ 60 Hz
Medium-speed (720-1000 rpm)
SMART mechanical
16DZD MeOH
Up to 3,536 kWm / 4,810 HP (continuous rating)
Up to 70% methanol - 30% (bio)diesel/HVO
Low Pressure Fuel Injection (< 10 bar)
Compact Fuel Preparation Compartment
12DZD MeOH
Up to 2,652 kWm / 3,610 HP (continuous rating)
Up to 70% methanol - 30% (bio)diesel/HVO
Low Pressure Fuel Injection (< 10 bar)
Compact Fuel Preparation Compartment
8DZD MeOH
Up to 1,768 kWm / 2,410 HP (continuous rating)
Up to 70% methanol - 30% (bio)diesel/HVO
Low Pressure Fuel Injection (< 10 bar)
Compact Fuel Preparation Compartment
6DZD MeOH
Up to 1,326 kWm / 1,800 HP (continuous rating)
Up to 70% methanol - 30% (bio)diesel/HVO
Low Pressure Fuel Injection (< 10 bar)
Compact Fuel Preparation Compartment
BeHydro 16DZD H2
Up to 2,670 kWm / 3,630 HP (continuous rating)
Up to 85% hydrogen - 15% (bio)diesel/HVO
Meets Gas Safe engine room standards
Can run on less purified hydrogen
BeHydro 12DZD H2
Up to 2,000 kWm / 2,720 HP (continuous rating)
Up to 85% hydrogen - 15% (bio)diesel/HVO
Meets Gas Safe engine room standards
Can run on less purified hydrogen
BeHydro 8DZD H2
Up to 1,330 kWm / 1,810 HP (continuous rating)
Up to 85% hydrogen - 15% (bio)diesel/HVO
Meets Gas Safe engine room standards
Can run on less purified hydrogen
BeHydro 6DZD H2
Up to 1,000 kWm / 1,360 HP (continuous rating)
Up to 85% hydrogen - 15% (bio)diesel/HVO
Meets Gas Safe engine room standards
Can run on less purified hydrogen
BeHydro 16DZ H2
Up to 2,670 kWm / 3,630 HP (continuous rating)
100% hydrogen
Meets Gas Safe engine room standards
Can run on less purified hydrogen
BeHydro 12DZ H2
Up to 2,000 kWm / 2,720 HP (continuous rating)
100% hydrogen
Meets Gas Safe engine room standards
Can run on less purified hydrogen
BeHydro 8DZ H2
Up to 1,335 kWm / 1,810 HP (continuous rating)
100% hydrogen
Meets Gas Safe engine room standards
Can run on less purified hydrogen
BeHydro 6DZ H2
Up to 1,000 kWm / 1,360 HP (continuous rating)
100% hydrogen
Meets Gas Safe engine room standards
Can run on less purified hydrogen
6DZD genset
Up to 950 kWe @ 50 Hz
Up to 855 kWe @ 60 Hz
Medium-speed (720-1,000 rpm)
SMART mechanical
16DZD
Up to 2,670 kWm
Gas/air mixing unit before turbo
Natural aspirated low pressure gas feeding
SMART mechanical
12DZD
Up to 2,000 kWm
Gas/air mixing unit before turbo
Natural aspirated low pressure gas feeding
SMART mechanical
8DZD
Up to 1,335 kWm
Gas/air mixing unit before turbo
Natural aspirated low pressure gas feeding
SMART mechanical
6DZD
Up to 1,000 kWm
Gas/air mixing unit before turbo
Natural aspirated low pressure gas feeding
SMART mechanical
16DZD genset
Up to 2,537 kWe @ 50 Hz
Up to 2,280 kWe @ 60 Hz
Medium-speed (720-1000 rpm)
SMART mechanical
12DZD genset
Up to 1,900 kWe @ 50 Hz
Up to 1,710 kWe @ 60 Hz
Medium-speed (720-1,000 rpm)
SMART mechanical
8DZD genset
Up to 1,268 kWe @ 50 Hz
Up to 1,140 kWe @ 60 Hz
Medium-speed (720-1,000 rpm)
SMART mechanical
16DZD MeOH genset
Up to 3,359 kWe / 4,199 kVA @ 50 Hz (continuous rating)
Up to 3,023 kWe / 3,779 kVA @ 60 Hz (continuous rating)
Up to 70% methanol - 30% (bio)diesel/HVO
Low Pressure Fuel Injection (< 10 bar)
12DZD MeOH genset
Up to 2,519 kWe / 3,149 kVA @ 50 Hz (continuous rating)
Up to 2,267 kWe / 2,834 kVA @ 60 Hz (continuous rating)
Up to 70% methanol - 30% (bio)diesel/HVO
Low Pressure Fuel Injection (< 10 bar)
8DZD MeOH genset
Up to 1,680 kWe / 2,100 kVA @ 50 Hz (continuous rating)
Up to 1,512 kWe / 1,890 kVA @ 60 Hz (continuous rating)
Up to 70% methanol - 30% (bio)diesel/HVO
Low Pressure Fuel Injection (< 10 bar)
6DZD MeOH genset
Up to 1,260 kWe / 1,575 kVA @ 50 Hz (continuous rating)
Up to 1,134 kWe / 1,417 kVA @ 60 Hz (continuous rating)
Up to 70% methanol - 30% (bio)diesel/HVO
Low Pressure Fuel Injection (< 10 bar)
BeHydro 16DZD H2 genset
Up to 2,537 kWe / 3,171 kVA @ 50 Hz (continuous rating)
Up to 2,280 kWe / 2,850 kVA @ 60 Hz (continuous rating)
Up to 85% hydrogen - 15% (bio)diesel/HVO
Can run on less purified hydrogen
BeHydro 12DZD H2 genset
Up to 1,900 kWe / 2,375 kVA @ 50 Hz (continuous rating)
Up to 1,710 kWe / 2,138 kVA @ 60 Hz (continuous rating)
Up to 85% hydrogen - 15% (bio)diesel/HVO
Can run on less purified hydrogen
BeHydro 8DZD H2 genset
Up to 1,268 kWe / 1,585 kVA @ 50 Hz (continuous rating)
Up to 1,140 kWe / 1,425 kVA @ 60 Hz (continuous rating)
Up to 85% hydrogen - 15% (bio)diesel/HVO
Can run on less purified hydrogen
BeHydro 6DZD H2 genset
Up to 950 kWe / 1,188 kVA @ 50 Hz (continuous rating)
Up to 855 kWe / 1,069 kVA @ 60 Hz (continuous rating)
Up to 85% hydrogen - 15% (bio)diesel/HVO
Can run on less purified hydrogen
BeHydro 16DZ H2 genset
Up to 2,537 kWe / 3,171 kVA @ 50 Hz (continuous rating)
Up to 2,280 kWe / 2,850 kVA @ 60 Hz (continuous rating)
100% hydrogen (ZERO emission)
Can run on less purified hydrogen
BeHydro 12DZ H2 genset
Up to 1,900 kWe / 2,375 kVA @ 50 Hz (continuous rating)
Up to 1,710 kWe / 2,138 kVA @ 60 Hz (continuous rating)
100% hydrogen (ZERO emission)
Can run on less purified hydrogen
BeHydro 8DZ H2 genset
Up to 1,268 kWe / 1,585 kVA @ 50 Hz (continuous rating)
Up to 1,140 kWe / 1,425 kVA @ 60 Hz (continuous rating)
100% hydrogen (ZERO emission)
Can run on less purified hydrogen
BeHydro 6DZ H2 genset
Up to 950 kWe / 1,188 kVA @ 50 Hz (continuous rating)
Up to 855 kWe / 1,069 kVA @ 60 Hz (continuous rating)
100% hydrogen (ZERO emission)
Can run on less purified hydrogen
16DV36 genset
Up to 10,126 kWe @ 50 Hz
Up to 9,720 kWe @ 60 Hz
Medium-speed (600-750 rpm)
2-stage turbocharging
12DV36 genset
Up to 7,594 kWe @ 50 Hz
Up to 7,290 kWe @ 60 Hz
Medium-speed (600-750 rpm)
2-stage turbocharging
8DL36 genset
Up to 5,063 kWe @ 50 Hz
Up to 4,860 kWe @ 60 Hz
Medium-speed (600-750 rpm)
2-stage turbocharging
6DL36 genset
Up to 3,797 kWe @ 50 Hz
Up to 3,645 kWe @ 60 Hz
Medium-speed (600-750 rpm)
2-stage turbocharging
16DZC genset
Up to 3,395 kWe @ 50 Hz
Up to 3,057 kWe @ 60 Hz
Medium-speed (720-1000 rpm)
SMART mechanical
12DZC genset
Up to 2,546 kWe @ 50 Hz
Up to 2,292 kWe @ 60 Hz
Medium-speed (720-1000 rpm)
SMART mechanical
8DZC genset
Up to 1,697 kWe @ 50 Hz
Up to 1,528 kWe @ 60 Hz
Medium-speed (720-1000 rpm)
SMART mechanical
6DZC genset
Up to 1,273 kWe @ 50 Hz
Up to 1,146 kWe @ 60 Hz
Medium-speed (720-1000 rpm)
SMART mechanical
16DZD genset
Up to 2,537 kWe @ 50 Hz
Up to 2,280 kWe @ 60 Hz
Medium-speed (720-1000 rpm)
SMART mechanical
12DZD genset
Up to 1,900 kWe @ 50 Hz
Up to 1,710 kWe @ 60 Hz
Medium-speed (720-1,000 rpm)
SMART mechanical
8DZD genset
Up to 1,268 kWe @ 50 Hz
Up to 1,140 kWe @ 60 Hz
Medium-speed (720-1,000 rpm)
SMART mechanical
6DZD genset
Up to 950 kWe @ 50 Hz
Up to 855 kWe @ 60 Hz
Medium-speed (720-1,000 rpm)
SMART mechanical
16DZC
Up to 3,536 kWm (continuous rating)
Up to 4,000 kWm for special applications *
SMART mechanical
Easy maintenance
12DZC
Up to 2,652 kWm (continuous rating)
Up to 3,000 kWm for special applications *
SMART mechanical
Easy maintenance
8DZC
Up to 1,768 kWm (continuous rating)
Up to 2,000 kWm for special applications *
SMART Mechanical
Easy maintenance
6DZC
Up to 1,326 kWm (continuous rating)
Up to 1,500 kWm for special applications *
SMART mechanical
Easy maintenance
Evolve 4EL23
Up to 1,320 kWm / 1,795 HP (continuous rating)
Medium-speed (750-1200 rpm)
Future-proof engine platform
Fuel flexibility (easy conversion from liquid fuel to dual fuel and 100% gas)
16DZD
Up to 2,670 kWm (continuous rating)
Gas/air mixing unit before turbo
Natural aspirated low pressure gas feeding
SMART mechanical
12DZD
Up to 2,000 kWm (continuous rating)
Gas/air mixing unit before turbo
Natural aspirated low pressure gas feeding
SMART mechanical
8DZD
Up to 1,335 kWm (continuous rating)
Gas/air mixing unit before turbo
Natural aspirated low pressure gas feeding
SMART mechanical
6DZD
Up to 1,000 kWm (continuous rating)
Gas/air mixing unit before turbo
Natural aspirated low pressure gas feeding
SMART mechanical
16DZD MeOH
Up to 3,536 kWm / 4,810 HP (continuous rating)
Up to 70% methanol - 30% (bio)diesel/HVO
Low Pressure Fuel Injection (< 10 bar)
Compact Fuel Preparation Compartment
12DZD MeOH
Up to 2,652 kWm / 3,610 HP (continuous rating)
Up to 70% methanol - 30% (bio)diesel/HVO
Low Pressure Fuel Injection (< 10 bar)
Compact Fuel Preparation Compartment
8DZD MeOH
Up to 1,768 kWm / 2,410 HP (continuous rating)
Up to 70% methanol - 30% (bio)diesel/HVO
Low Pressure Fuel Injection (< 10 bar)
Compact Fuel Preparation Compartment
6DZD MeOH
Up to 1,326 kWm / 1,800 HP (continuous rating)
Up to 70% methanol - 30% (bio)diesel/HVO
Low Pressure Fuel Injection (< 10 bar)
Compact Fuel Preparation Compartment
BeHydro 16DZD H2
Up to 2,670 kWm / 3,630 HP (continuous rating)
Up to 85% hydrogen - 15% (bio)diesel/HVO
Meets Gas Safe engine room standards
Can run on less purified hydrogen
BeHydro 12DZD H2
Up to 2,000 kWm / 2,720 HP (continuous rating)
Up to 85% hydrogen - 15% (bio)diesel/HVO
Meets Gas Safe engine room standards
Can run on less purified hydrogen
BeHydro 8DZD H2
Up to 1,330 kWm / 1,810 HP (continuous rating)
Up to 85% hydrogen - 15% (bio)diesel/HVO
Meets Gas Safe engine room standards
Can run on less purified hydrogen
BeHydro 6DZD H2
Up to 1,000 kWm / 1,360 HP (continuous rating)
Up to 85% hydrogen - 15% (bio)diesel/HVO
Meets Gas Safe engine room standards
Can run on less purified hydrogen
BeHydro 16DZ H2
Up to 2,670 kWm / 3,630 HP (continuous rating)
100% hydrogen
Meets Gas Safe engine room standards
Can run on less purified hydrogen
BeHydro 12DZ H2
Up to 2,000 kWm / 2,720 HP (continuous rating)
100% hydrogen
Meets Gas Safe engine room standards
Can run on less purified hydrogen
BeHydro 8DZ H2
Up to 1,335 kWm / 1,810 HP (continuous rating)
100% hydrogen
Meets Gas Safe engine room standards
Can run on less purified hydrogen
BeHydro 6DZ H2
Up to 1,000 kWm / 1,360 HP (continuous rating)
100% hydrogen
Meets Gas Safe engine room standards
Can run on less purified hydrogen
16DV36
Up to 10,400 kWm (continuous rating)
Medium-speed (600-750 rpm)
Fuel flexibility
2-stage turbocharging
12DV36
Up to 7,800 kWm (continuous rating)
Medium-speed (600-750 rpm)
Fuel flexibility
2-stage turbocharging
8DL36
Up to 5,200 kWm (continuous rating)
Medium-speed (600-750 rpm)
Fuel flexibility
2-stage turbocharging
6DL36
Up to 3,955 kWm (continuous rating)
Medium-speed (600-750 rpm)
Fuel flexibility
2-stage turbocharging
16DZC
Up to 3,536 kWm (continuous rating)
Up to 4,000 kWm for special applications *
Fuel flexibility
SMART mechanical
12DZC
Up to 2,652 kWm (continuous rating)
Up to 3,000 kWm for special applications *
Fuel flexibility
SMART mechanical
8DZC
Up to 1,768 kWm (continuous rating)
Up to 2,000 kWm for special applications *
Fuel flexibility
SMART Mechanical
6DZC
Up to 1,326 kWm (continuous rating)
Up to 1,500 kWm for special applications *
Fuel flexibility
SMART mechanical
16DV36 genset
Up to 10,126 kWe @ 50 Hz
Up to 9,720 kWe @ 60 Hz
Medium-speed (600-750 rpm)
2-stage turbocharging
12DV36 genset
Up to 7,594 kWe @ 50 Hz
Up to 7,290 kWe @ 60 Hz
Medium-speed (600-750 rpm)
2-stage turbocharging
8DL36 genset
Up to 5,063 kWe @ 50 Hz
Up to 4,860 kWe @ 60 Hz
Medium-speed (600-750 rpm)
2-stage turbocharging
6DL36 genset
Up to 3,797 kWe @ 50 Hz
Up to 3,645 kWe @ 60 Hz
Medium-speed (600-750 rpm)
2-stage turbocharging
16DZC genset
Up to 3,395 kWe @ 50 Hz
Up to 3,057 kWe @ 60 Hz
Medium-speed (720-1000 rpm)
SMART mechanical
12DZC genset
Up to 2,546 kWe @ 50 Hz
Up to 2,292 kWe @ 60 Hz
Medium-speed (720-1000 rpm)
SMART mechanical
8DZC genset
Up to 1,697 kWe @ 50 Hz
Up to 1,528 kWe @ 60 Hz
Medium-speed (720-1000 rpm)
SMART mechanical
6DZC genset
Up to 1,273 kWe @ 50 Hz
Up to 1,146 kWe @ 60 Hz
Medium-speed (720-1000 rpm)
SMART mechanical